| 首 --页 | 电梯常识 | 相关法规 | 行业动态 | 名牌介绍 | 节能改造 | 技术交流 | 相关下载 | 访客留言 | 免费信息 | 人才交流 | 电梯论坛 |
![]() |
![]() |
||
| 电梯技术交流 |
三菱GPS-III详细故障代码说明 MON1=1 MON0=0: 7SEG1=1:INV温度检测; =2:E-STOP次 =3:CC-WDT三次 =4:SLCWDT三次 =5:电机过电流 =6:制动器电阻过载 =7:接触器故障 =8:终端减速开关故障 =9:平层开关故障 =A:称量装置故障 =B:E1板故障 =C:UHS/DHS开关故障 =D:DZ检测回路故障 =E\F:无 MON0=1: 7SEG1=1:远程复位检测; =2:选层器错误16次 =3:串行故障 =4:电容器容量不足 =5:手动运行按钮故障 =6:速度图形跳转5次 =7:#LB接触器动作失败5次 =8:#5接触器动作失败5次 =9:#BK1接触器动作失败5次 =A:#BK2接触器动作失败5次 =B:LVLT5次 =C:E1板故障 =D:风扇故障 =E\F:风扇或E1板故障 MON0=2: 7SEG1=1:#5 ON故障; =2:E-STOP两次 =3:系统故障 =4:再复位请求 =5:PCB基极驱动故障 =6:DC-CT故障 =7:无 =8:浸水感应器故障 =9:反浸水动作结束 =A:#PWD开关指令持续三分钟 =B:扶手开关保持 =C:制动器拖动运行结束 =D:制动器再动作故障 =E:无 =F:选层器故障运行16次 MON0=3: 7SEG1=1:MELD过载; =2:异常低速 =3:异常高速 =4:反转定时 =5:反向运行 =6:反转定时器(CWT) =7:反转定时器(CWT BS标准) =8:逆变器过电压 =9:逆变器欠电压 =A:CC-WDT四次 =B:SLC-WDT 4次 =C:逆变器过电流 =D:SLC E-STOP =E:编码器故障(自动) =F:编码器故障(手动) MON0=4: 7SEG1=1:两次E-STOP; =2:INV欠电压 =3:E-STOP F/F复位 =4:#LB线圈故障 =5:#5线圈故障 =6:#BK1线圈故障 =7:#BK2线圈故障 =8:上电 =9:无 =A:无 =B:逆变器充电失败 =C\D\E\F:无 MON0=5: 7SEG1=1:电气安全回路 =2:#29锁存 =3:断电 =4:INV欠电压 =5:12V电源故障 =6:控制屏打开 =7:手动过载运行 =8:驱动S/W E-STOP =9:管理S/W E-STOP =A:无 =B:异常制动器滑动距离 =C\D\E\F:无 MON0=6: 7SEG1=1:逆变器欠压; =2:PCB基极驱动故障 =3:INV保护回路动作 =4:#29锁存 =5:12V电源故障 =6:温度开关超75度 =7:温度开关超90度 =8:温度开关冷却/接插件断线 =9:逆变器过电流 =A:逆变器过电压 =B:断电(DC电源故障) =C:E1板警告 =D:DC电源故障 =E:AC电源故障 =F:#PWD(电源故障检出) MON0=7: 7SEG1=1:CC-WDT 5次; =2:CC-WDT 4次 =3:CC-WDT 3次 =4:SLC-WDT 5次 =5:SLC-WDT 4次 =6:SLC-WDT 3次 =7\8\9\A\B:无 =C:称量印板低于30度 =D:称量印板低于30-40度 =E:称量印板超过60度 =F:称量装置A/D转换 MON0=8: 7SEG1=1:#BK1过电流; =2:#BK2过电流 =3:#BK1 DC-CT断线 =4:#BK2 DC-CT断线 =5:#BK1线圈故障 =6:#BK2线圈故障 =7:#BK1线圈短路 =8:#BK2线圈短路 =9:#BK1 DC-CT故障 =A:#BK2 DC-CT故障 =B:#BK1 线圈全部短路 =C\D\E\F:无 MON0=9: 7SEG1=1:驱动E-STOP =2:电机过电流 =3:不能再启动(驱动S/W) =4:MELD过载运行 =5:TSD开关故障 =6:称量装置故障 =7:DC-CT故障 =8:TSD运行 =9:编码器Z相故障 =A:编码器F相故障 =B:带定时器电机过电流检测 =C\D:无 =E:门切断回路故障 =F:无 MON0=A: 7SEG1=1:图形-转速跳转 =2:速度图形跳转异常 =3:驱动S/W E-STOP =4:再生电阻过载 =5:无 =6:手动过载运行 =7:MCP逆变器过电流 =8:TSD-PAD故障 =9:称量装置传送故障 =A:称量装置温度异常 =B\C\D\E\F:无 MON0=B: 7SEG1=1:10分钟不能用 =2:16分钟不能用 =3:不能再启动10分钟 =4:不能运行10分钟 =5:不能开门2分钟 =6:熔丝故障2分钟 =7:#60故障 =8:不能开门 =9:操纵厢故障 =A:门传感器ON故障 =B:关人警告 =C:使用不能警告 =D:群控故障 =E:电源故障(层站) =F:门感应器OFF故障 MON0=C: 7SEG1=1:SLC传送故障 =2:SLC-E STOP =3:SLC异常高速 =4:SLC反转定时器 =5:开门运行检出 =6:SLC RAM故障 =7-F:无 MON0=D: 7SEG1=1:前门BC-CPU1故障 =2:前门BC-CPU2故障 =3:前门BC-CPU3故障 =4:前门BC-CPU4故障 =5:前门CS-CPU故障 =6:前门DC-CPU故障 =7:前门IC-CPU故障 =8:前门CZ-CPU故障 =9:SC-CPU故障 =A:SH-CPU故障 =B:SC-CPU故障 =C:SH-CPU故障 =D:HS-CPU故障 =E\F:无 MON0=E: 7SEG1=1:后门BK-CPU5异常 =2:后门BC-CPU6异常 =3:后门BC-CPU7异常 =4:后门BC-CPU8异常 =5:后门CS-CPU异常 =6:后门DC-CPU异常 =7:后门IC-CPU异常 =8:后门CZ-CPU异常 =9:#BK1接触器动作失败5次 |
|
| 浅谈电梯设备故障的另类处理方法 通用型电梯轿厢到站钟介绍 电梯通用无线遥控报警机 谈在用电梯改造的效益/服务中心 无机房电梯设计应注意哪些事项 普通自动扶梯智能化节电改造可行性报告 介绍一种控制电梯部分层站工作与否的简单方法 自动扶梯变频节能改造 谈电梯设备的定期维护保养 米高2000故障代码显示 永大NTVF电梯故障分析之一(TCD11-15) OTIS/DO2000门机以及控制系统代码 富士达故障代码识别 韩国现代SHVF4电梯元气件代号说明 三菱电梯GPS--3维修资料 GPS-I电子板上各发光管指示功能一览表 深圳市中油酒店自动扶梯节能改造成功 电梯通用无线对讲装置研究成功 通用型电梯轿厢到站钟介绍 电梯通用无线遥控报警机 谈谈自动扶梯节能改造应注意的相关事项 东芝CV180常用地址 东芝CV55 SM MODE 异常表 东芝150,160,320在板PUM,PUS调阅故障的方法 OTIS故障解决集锦集锦 异步电机控制柜富士G11UD参数设置表 三菱GPS-III故障代码 三菱GPS-3故障码显示-E12士力驼16次异常检出 三菱GPS-3电梯电路板讲解 日立电梯故障维修示例 日立电梯故障分析 富士达电梯控制屏的操作方法 东芝OBM操作说明 东芝CV180故障诊断使用说明 GPS-3电梯P1板(KCD-70X)开关名称及功能说明 三菱GPS-III详细故障代码说明 GPS-II电梯平层精度及舒适感调整方法 SPVF(VFCL)电梯控制柜主要电脑板及发光管说明 GPS-I电梯网络控制系统关键处理器名称及位置 三菱SPVF电梯常见故障处理 讯达300P电梯故障代码 |
||